Précédent Suivant
Vendu le 
16-04-28
Meilleure enchère
US 433 000 $
Acheté avec  Prix d'achat immédiat
Nb d'enchères 
1
VENDU!
DÉTAILS RELATIFS À L'ARTICLE
Relevé du compteur
94 Heures
Nº  de série
15.6 cu yd Aggregate Hopper w/ Weigh System & Removable Division Plate Allowing Two Materials to be Mixed, Variable Speed Belt Feeder, Twin Shaft Continuous Mixer on Discharge Conveyor, 55 US tons (50 tons) Self-Erecting Cement/Binder Silo w/Variable Speed Rotary Valve, 20 m2 Reverse Air Jet Fan Assisted Type Filter System Mounted on Silo Roof, 1750 litres (462 galls) Water System w/Pumps & Weigh System, 200 kVA, 3 phase, 480/277 volts, 60 Hz Gen-Set, On-Board Plant Control & Starter Panels, On-Board Air Compressor and Hydraulic Supply

Rapport d'inspection



En tant qu'acheteur, veuillez noter que vous êtes responsable de l'examen de la totalité du rapport d'inspection lors de l'évaluation d'un article.


Current Photos
Description Évaluation Détails  
(48)


Seller Photos (prior to inspection)
Description Évaluation Détails  
(30)
 

Analyse d'échantillon d'huile
  engine hydraulic
date of analysis Nov 18, 2014 Nov 18, 2014
Lead 9.41 PPM 0 PPM
Chromium 2.24 PPM 0.17 PPM
Copper 29.9 PPM 1.06 PPM
Silver 0 PPM 0 PPM
Nickel 1.01 PPM 0.77 PPM
Tin 0 PPM 1.03 PPM
Aluminum 2.31 PPM 0.24 PPM
Silicon 86.43 PPM 5.91 PPM
Iron 38.95 PPM 7.04 PPM
Glycol NEG N/A
Water NEG N/A
Fuel <5% N/A
Réclamations :
This item is offered with IronClad Assurance® protection. With IronClad Assurance®, if a buyer discovers that the item is not substantially in the condition as represented in this inspection report, the buyer may submit a written dispute claim to IronPlanet. Following submission of a written dispute claim, IronPlanet will investigate the claim, re-inspecting the equipment item as necessary, and determine a fair and mutually beneficial resolution. Please note that IronPlanet inspections are performed solely for the purpose of reporting the visible condition of the equipment's major systems and attachments on the day of the inspection and do not include load testing or digging/lifting. These inspections are not designed nor intended to detect latent defects, or conditions that could only be found in connection with the physical dismantling of the equipment or the use of diagnostic tools or techniques. This inspection report includes ratings, comments, and photos of the various components of the item. Knowledgeable buyers are expected to carefully review all of the available information in the inspection report, including all photographs, in order to make the best bidding and buying decision possible.